Our water separators have been designed for the removal of bulk liquid water and particulate from compressed air and gases. Unique centrifugal action removes contaminants at low-pressure drop for maximum energy saving and are available from 1/4”-3” pipe sizes and extend to 2200 m3/h (1294 cfm).

Note 1: Even high efficient condensate separators cannot remove 100% of the oil from the air stream calling for coalescing and particulate filters to be installed to remove the fine traces of oil, water and particles.

Note: Automatic drain valves are fitted as standard. All separator bodies are coated with electrostatic powder paint finish both inside and out.

 

Correction Factor

For maximum flow rate, multiply model flow rate show in the above table by the correction factor corresponding to the working pressure.


Technical Specifications

Mikropor Compressed Air Filters have been designed to meet all requirements of the compressed air filtration needs. These air filters provide more comfortable usage, higher efficiency, lower pressure drop and more port size options to the end users.

Filtration

Due to our usage of deep pleating technique, the filtration area is significantly increased remarkably, which leads to a better filtration and higher dirt holding capacity. Mikropor Compressed Air Filters have been designed to remove air borne contamination in compressed air stream, delivering energy efficient operation and reliable performance.




​Features

Our air filters of four efficiency ratings, start with 0.01 micron at up to 290 psi (20 bar)-1/4” and extend to 3” NPT/BSP pipe sizes. A protected auto float drain (2 mm orifice) is standard for optimal and reliable removal of liquid contaminants.

These air filters have a zero-porosity aluminum and durable epoxy powder-coating finish along with a corrosion-resistant internal coating for a long service life. Filter combinations are configured to meet specific application requirements. Filters comply with PED and perform as per related ISO 8573 standards. These filters could be equipped with differential pressure gauges for easy maintenance and energy efficiency.

Mikropor compressed air filters are always recommended with this system.


Types of Compressed Air Filters

P Pre-Filter / Particulate Filter (Filter/Element air flow direction is outside to inside)

X General Purpose Filter / Water Removal (Filter/Element air flow direction is inside to outside)

Y Coalescing Filter / Oil Removal (Filter/Element air flow direction is inside to outside)

A Activated Carbon Filter / Odor Removal (Filter/Element air flow direction is outside to inside)


Correction Factor

For maximum flow rate, multiply model flow rate show in the above table by the correction factor corresponding to the working pressure.

Technical Specifications

Note:

1) Grade A must not operate in oil saturated conditions.
2) Grade A elements should be replaced periodically to suit the applications but must be changed at least every six months.
3) Grade A will not remove certain gases including carbon monoxide and carbon dioxide. Please refer to works if in doubt.
4) Flow rates are based on a 7 bar operating pressure, for flows at other pressures use correction factor given above.
5) All filters are suitable for use with mineral and synthetic oils.
6) Gauge type pressure indicators are fitted to models G20 to G2620 as standard.
7) All filters are in conformity with the Pressure Equipment Directive (97/23/EC).

GO Series Compressed Air Filters

​New additional to our G series, Mikropor GO series compressed air filters are designed for easy element replacement for “zero clearance” ability.


Features

Our air filters of four efficiency ratings, start with 0.01 micron at up to 290 psi (20 bar)-1/4” and extend to 3” NPT/BSP pipe sizes. A protected auto float drain (2 mm orifice) is standard for optimal and reliable removal of liquid contaminants.

These air filters have a zero-porosity aluminium and durable epoxy powder-coat finish, along with a corrosion-resistant internal coating for a long service life. Filter combinations are configured to meet specific application requirements. Filters comply with PED and perform as per related ISO 8573 standards. These filters may be equipped with differential pressure gauges for easy maintenance and energy efficiency.


Element Features

Our Mikropor elements offer a wide range of 1 micron to 0,01 micron. Durable element construction and efficient drain layer ensures continued performance with optimal element change intervals. Elements are also easy to replace with the head clips.


Mikropor Elements Have Been Designed for Easy Handling

1-  Deep pleating leads to lower pressure drop.

2- Supreme collapse resistance due to usage of fluted stainless tube, providing strength against pressure drops while improving the performance by passing air diagonally through the element.

3- PVC impregnated foam favors water/oil drainage.




Head Clamping

Head Clamping provides serial connection of filters without any extra piping


Drainage Ribs

Drainage Ribs favors the humidity flow.


Correction Factor

For maximum flow rate, multiply model flow rate show in the above table by the correction factor corresponding to the working pressure.




Zero Clearance

A major innovation for servicing the zero clearance design gives a quicker, easier, simpler filter change, with no need for any specialist tools.

Anodising

Anodising provides supreme corrosion resistance. Anodised surface treatment is proven to be better than other surface treatment methods such as Alocrome coating.


Technical Specifications

Note:

1) Grade A must not operate in oil saturated conditions.
2) Grade A elements should be replaced periodically to suit the applications but must be changed at least every six months.
3) Grade A will not remove certain gases including carbon monoxide and carbon dioxide. Please refer to works if in doubt.
4) Flow rates are based on a 7 bar operating pressure, for flows at other pressures use correction factor given above.
5) All filters are suitable for use with mineral and synthetic oils.
6) Gauge type pressure indicators are fitted to models G20 to G2620 as standard.
7) All filters are in conformity with the Pressure Equipment Directive (97/23/EC).


Need More Information?



Send Us an Inquiry